Onsite Generation Options for Data Centers: Implications for Data Center Flexibility

September 30, 2026

Rapid growth in artificial intelligence and high-density digital workloads is driving unprecedented demand for new data center capacity, but grid interconnection delays and transmission constraints increasingly limit the ability to secure reliable power. As a result, onsite generation, ranging from uninterruptible power supply systems and emergency backup generators to peaking units, primary power, and bridging power, has become central to data center design.

(Public) Tech In Focus: Jenbacher Spark-Ignition Engines

September 29, 2026

This Quick Insight provides an overview of Jenbacher J620, J624, and J920 spark-ignition engines for data center onsite generation. Its scope includes emergency backup, bridging, primary power, peaking, and combined heat-and-power applications, including data center cooling. The solution maturity discussion addresses natural-gas, biofuel, and hydrogen operation. 

Tech Performance Evaluation Report: INNIO Jenbacher Spark-Ignition Engines

September 29, 2026

This technical update reviews INNIO Jenbacher spark-ignition natural-gas engines for onsite generation at data centers and examines their relationship to EPRI’s DCFlex vision and Flex MOSAIC™ classification framework. It addresses primary generation, peaking, bridging generation while awaiting grid interconnection, emergency backup, and grid support applications. The scope includes product overviews, solution details, and previous deployments, with attention to the J620, J624, and J920 models. Emerging combined heat-and-power and hydrogen capabilities are also considered.

Evaluating Resource Portfolio Readiness for Data Center Loads: Metrics and Approaches

August 14, 2026

This white paper introduces a set of metrics for assessing portfolio readiness in the context of data center load growth. It provides an overview of the challenges system resource planners encounter when integrating data center loads and introduces metrics that can be incorporated into the resource planning process to address these challenges. The paper also explores how these metrics fit within the broader portfolio planning framework. The developed framework and metrics were informed by an extensive review of existing frameworks and literature along with a series of expert interviews.

(Public) DCFlex Demonstration of Cleaner Backup Power: Field-Validated Emissions Performance of Hydrotreated Vegetable Oil (HVO) in Data Center Backup Generators

July 29, 2026

As part of EPRI’s DCFlex initiative, a field demonstration was conducted to evaluate hydrotreated vegetable oil (HVO) as an alternative fuel for backup diesel generators used in data centers. The project compared HVO and conventional fossil diesel under real-world operating conditions at a data center facility in Dallas, Texas, using a 2 MW backup generator.

Distribution-Connected Data Centers: Boundaries, Drivers, and Use-Cases

July 23, 2026

This report examines what constitutes a distribution-connected data center (DxDC), emphasizing that classification depends on more than voltage level or facility size; it is shaped by interconnection configuration, planning practices, jurisdictional treatment, operational visibility, and administrative considerations. The paper explores the diverse drivers behind distribution-level interconnection, with time-to-power emerging as the primary motivation, while highlighting that distribution connection does not eliminate underlying grid constraints or transmission impacts.

Managing Oscillating Load Impacts from Data Centers on Synchronous Machines: A Framework for Estimating Acceptable Load Oscillation Limits to Minimize Turbine-Generator Shaft Impacts

July 15, 2026

This report examines how data center load behavior may affect synchronous generator reliability. Large data centers, especially those supporting AI, can create cyclical and oscillatory demand patterns that differ from traditional loads and introduce new operational challenges. The report describes how these load oscillations can interact torsionally with synchronous turbine-generator shafts, amplifying mechanical stress, accelerating fatigue, and reducing reliability.

DCFlex Load Shape Library - Web Tool

July 7, 2026

The DCFlex Load Shape Library provides access to standardized hourly data center load shapes derived from measured power consumption data from multiple facilities. The library enables users to explore, visualize, and compare demand characteristics across different facility sizes, ownership models, and workload types.

Energy Supply Chain Resilience for Rapid Load Growth: Implications for Utilities and Data Center Expansion

June 30, 2026

This report examines the rapidly evolving supply chains supporting data center energy infrastructure amid accelerating load growth and increasing pressure on electrical generation equipment. Since EPRI’s 2025 assessment, the industry has reached several key milestones, including record-high gas turbine orders, longer transformer lead times, and the emergence of gigawatt-scale fuel cell procurement as a mainstream planning option. At the same time, solar power continued to dominate new U.S. generation additions despite a decline in total installations compared with 2024.